PTFE Thermocouple Cable Type K
Product Description
1. Introduction:
Thermocouple Extension cable is usually used to connect thermocouple and display-controled meters in order to lower the inaccuracy caused by temperature change on the connections.
2. Construction:
Conductor: original thermocoupole alloy material, in solid wire or strand wires
Insulation Layer:
Fiberglass (ambient temperature range 0-300ºC
PVC (ambient temperature range 0-105ºC)
TF (ambient temperature range 0-350ºC)
Silicone rubber (ambient temperature range 0-180ºC)
Jacket layer materials: fiberglass, PVC, TF, silicone rubber
Galvanized layer: stainless steel, tinned brass
3.Standard: conforms to IEC584 standard.
4. Color Code:Table 1
Product Parameters
TF Thermocouple Wire
Conductors
Wire Sizes(mm) |
Section(mm²) |
AWG |
2x1/0.2 |
Approx.0.03 |
32 |
2x1/0.5 |
Approx.0.20 |
24 |
2x1/0.65 |
Approx.0.33 |
22 |
2x1/0.8 |
Approx.0.50 |
20 |
2x7/0.2 |
Approx.0.22 |
24 |
2x7/0.3 |
Approx.0.50 |
20 |
2x6/0.32 |
Approx.0.48 |
20 |
Color code:
- ANSI: American standard
- DIN: Germany standard
- BS:Britain standard
- NFC: France Standard
- JIS: Japan Standard
- IEC:IEC standard
Type available: K, J, E, T, N, S
1 *Constructure: (TF + TF)
- Conductors are TF insulated
- Overall TF jacket
- Max. Environment temperature : 200ºC
2. *Constructure: TF+TF (TF + TF Twisted )
- Conductors are TF insulated
- Two wires twisted
- Overall TF jacket,
- Max. Environment temperature : 200ºC
3. *Constructure: TF + Stainless Steel Braided (TF + SSB )
- Conductors are TF insulated
- Overall stainless steel braided jacket.
- Max. Environment temperature : 200ºC
4. *Constructure: TF+ Stainless Steel Braided+ TF (TF + SSB +TF )
- Conductors are TF insulated
- Stainless steel braided for shieding in the middle
- Overall TF jacket.
- Max. Environment temperature : 200ºC
7. How to select:Order Code: e.g.
1 2 3 4 5 6
1 Thermocouple Types: K, J, E, T, N, S RTD: Cu, Ni
2 Conductot dimension:
2*7/0.3 means 2 cores, each core includes 7 strands wire,
each wire diameter is 0.3mm, more example: 2×7/0.2, 2×4/0.65, 2×1/0.3 etc.
Other way to symbol the conductor dimensions:
Conductor square meter: 0.25mm²
AWG standard (see*Table 2)
3 Insulated layer materials:
FG: fiberglass PVC: PVC TF SR: silicone rubber
4 Jacket layer material
FG: fiberglass PVC: PVC TF SR: silicone rubber
5 Galvanized Layer material: SS: stainless steel TB: tinned brass
6Color Code:
ANSI: American standard DIN: Germany standard BS:Britain standard
NFC: France Standard JIS: Japan Standard IEC: IEC standard
Detailed Photos
8. Photos for reference.