• Thermocouple Extension Wire Type K / J / E / N / T / R / S / B
  • Thermocouple Extension Wire Type K / J / E / N / T / R / S / B
  • Thermocouple Extension Wire Type K / J / E / N / T / R / S / B
  • Thermocouple Extension Wire Type K / J / E / N / T / R / S / B
  • Thermocouple Extension Wire Type K / J / E / N / T / R / S / B
  • Thermocouple Extension Wire Type K / J / E / N / T / R / S / B

Thermocouple Extension Wire Type K / J / E / N / T / R / S / B

Certification: ISO9001, CE
Type: Type J K N S T
Material: Ni-Fe
Samples:
US$ 0/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Thermocouple Extension Wire Type K / J / E / N / T / R / S / B pictures & photos
Thermocouple Extension Wire Type K / J / E / N / T / R / S / B
US $0.4-1.5 / Meter
Min. Order: 300 Meters
Diamond Member Since 2018

Suppliers with verified business licenses

Secured Trading Service
Trading Company
  • Overview
  • Product Description
Overview

Basic Info.

Model NO.
Type K / J / E / N / T / R / S / B
Form
Heating Wire
Shape
Tubular
Conductor Type
Solid, Solid or Stranded
Insulated
Fiberglass, PVC, FEP, PFA
Standard
ANSI, JIS, IEC
Shielding Materials
Silver or Tinned Copper
Packing
Wooden Case
Usage
Industrial
Transport Package
in Roll
Specification
2*7/0.2
Trademark
no
Origin
China
HS Code
8544491900
Production Capacity
10, 0000

Packaging & Delivery

Package Size
27.00cm * 27.00cm * 27.00cm
Package Gross Weight
6.000kg

Product Description

20AWG PVC Thermocouple Extension Wire Type K / J / E / N / T / R / S / B
 
Product Description

 

1. Introduction:
Thermocouple Extension cable is usually used to connect thermocouple and display-controled meters in order to lower the inaccuracy caused by temperature change on the connections.

2. Construction:  
Conductor: original thermocoupole alloy material, in solid wire or strand wires
Insulation Layer:
Fiberglass              (ambient temperature range 0-300ºC
 PVC                       (ambient temperature range 0-105ºC)
 TF                         (ambient temperature range 0-350ºC)
 Silicone rubber   (ambient temperature range 0-180ºC)
Jacket layer materials: fiberglass, PVC, TF, silicone rubber
Galvanized layer: stainless steel, tinned brass

3.Standard: conforms to IEC584 standard.

4. Color Code:Table 1
Thermocouple Extension Wire Type K / J / E / N / T / R / S / B


1, SUBJECT
This specification covers the requirements for PVC insulated, PVC
sheathed thermocouple extension cable, 2×7/0.3mm, strand wire, standard tolerance and color code.

2, TECHNICAL FEATURES
Thermocouple Extension Wire Type K / J / E / N / T / R / S / B

A. Conductors:
Stranded thermocouple extension wire
                                           
       Conductors Size(AWG)        NO.of Strands &Gauge  
       20        7/0.3mm

                                           
B. Insulation:
PVC(105ºC)
                       
       Nominal Insulation Thickness        0.15mm±0.2                                  

Color code
                                                                   
       Positive          Color                Negative          Color        
       Chromel        Yellow        Alumel        Red

                                           
C. Assembly:
Two conductors (positive and negative) parallel construction.

D. Overall Jacket
Extruded PVC(105ºC)
                                           
       Nominal Sheath Thickness        0.62mm±0.2                            
       Color code        Yellow

                       
3, DIMENSIONS AND TOLERANCES
                       
       Dimensions/tolerances(mm)        2.62±0.25*3.65±0.25                

                               
4, CALIBRATION TOLERANCE
                                                       
       Temperature range        Standard tolerance        Special tolerance
       0º to 200ºC        ±2.2ºC or 0.75%        ±1.1ºC or 0.4%

Thermocouple extension wire type available: KX, JX, TX, EX, NX, RX,SX and other
compensating cable like KCA, KCB and so on.
Besides those wires, we can also produce according to your demand.

7. How to select:Order Code: e.g.
J 2*7/0.3 FG FG SS DIN
  1                           2                                  3                                     4                          5                       6

1  Thermocouple Types: K, J, E, T, N, S          RTD: Cu, Ni

2  Conductot dimension:
2*7/0.3 means 2 cores,  each core includes 7 strands wire,
each wire diameter is 0.3mm, more example: 2×7/0.2, 2×4/0.65, 2×1/0.3 etc.
Other way to symbol the conductor dimensions:
Conductor square meter: 0.25mm²
AWG standard (see*Table 2)

3 Insulated layer materials:
FG: fiberglass   PVC: PVC      TF       SR: silicone rubber

4 Jacket layer material
FG: fiberglass   PVC: PVC      TF        SR: silicone rubber

5 Galvanized Layer material:   SS: stainless steel  TB: tinned brass

6Color Code:
ANSI: American standard   DIN: Germany standard    BS:Britain standard
NFC: France Standard          JIS: Japan Standard           IEC: IEC standard

8. Photos for reference.
Thermocouple Extension Wire Type K / J / E / N / T / R / S / B
Thermocouple Extension Wire Type K / J / E / N / T / R / S / B
Thermocouple Extension Wire Type K / J / E / N / T / R / S / B




 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Thermocouple Extension Wire Type K / J / E / N / T / R / S / B pictures & photos
Thermocouple Extension Wire Type K / J / E / N / T / R / S / B
US $0.4-1.5 / Meter
Min. Order: 300 Meters
Diamond Member Since 2018

Suppliers with verified business licenses

Secured Trading Service
Trading Company
Registered Capital
500000 RMB
Plant Area
<100 square meters