J PFA Thermocouple Wire Thermocouple Cable Electric Wire Type
Product Description
1. Introduction:
Thermocouple Extension cable is usually used to connect thermocouple and display-controled meters in order to lower the inaccuracy caused by temperature change on the connections.
2. Construction:
Conductor: original thermocoupole alloy material, in solid wire or strand wires
Insulation Layer:
Fiberglass (ambient temperature range 0-300ºC
PVC (ambient temperature range 0-105ºC)
PFA (ambient temperature range 0-260ºC)
Silicone rubber (ambient temperature range 0-180ºC)
Jacket layer materials: fiberglass, PVC, PFA, silicone rubber
Galvanized layer: stainless steel, tinned brass
3.Standard: conforms to IEC584 standard.
4. Color Code:Table 1
Thermocouple Compensation Cable Type EX-FEP/FEP/SSB
1, SUBJECT
This specification covers the requirements for FEP insulated, FEP sheathed
thermocouple extension cable, type EX, , stranded wire.
2, TECHNICAL FEATURES
A. Conductors:
Stranded thermocouple extension wire
Conductors Size(AWG) |
NO.of Strands &Gauge |
22 |
0.6mm |
B. Insulation:
Extruded FEP ( 200ºC)
Nominal Insulation Thickness |
0.21mm±0.2mm |
Color code
Positive |
Color |
Negative |
Color |
Chromel |
Purple |
Alumel |
Red |
C. Assembly:
Two conductors (positive and negative) parallel construction.
D. Overall Jacket
Extruded FEP ( 200ºC)
Nominal Sheath Thickness |
0.25mm±0.2 |
Color code |
Purple |
3, DIMENSIONS AND TOLERANCES
Dimensions/tolerances(mm) |
1.65±0.25×2.50±0.25 |
4, CALIBRATION TOLERANCE
Temperature range |
Standard tolerance |
Special tolerance |
0º to 200ºC |
±2.2ºC or 0.75% |
±1.1ºC or 0.4% |
Thermocouple extension wire type available: KX, JX, TX, EX, NX, RX,SX and other compensating
cable like KCA, KCB and so on.
Besides those wires, we can also produce according to your demand.
7. How to select:Order Code: e.g.
1 2 3 4 5 6
1 Thermocouple Types: K, J, E, T, N, S RTD: Cu, Ni
2 Conductot dimension:
2*7/0.3 means 2 cores, each core includes 7 strands wire,
each wire diameter is 0.3mm, more example: 2×7/0.2, 2×4/0.65, 2×1/0.3 etc.
Other way to symbol the conductor dimensions:
Conductor square meter: 0.25mm²
AWG standard (see*Table 2)
3 Insulated layer materials:
FG: fiberglass PVC: PVC TF: PFA, FEP SR: silicone rubber
4 Jacket layer material
FG: fiberglass PVC: PVC TF: PFA, FEP SR: silicone rubber
5 Galvanized Layer material: SS: stainless steel TB: tinned brass
6Color Code:
ANSI: American standard DIN: Germany standard BS:Britain standard
NFC: France Standard JIS: Japan Standard IEC: IEC standard
8. Photos for reference.