Fiberglass Rtd Extension Wire Compensation Cable

Product Details
Customization: Available
Type: Type J K N S T
Conductor Type: Solid, Solid or Stranded
Still deciding? Get samples of US$ 0/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2018

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
500000 RMB
Plant Area
<100 square meters
  • Fiberglass Rtd Extension Wire Compensation Cable
  • Fiberglass Rtd Extension Wire Compensation Cable
  • Fiberglass Rtd Extension Wire Compensation Cable
  • Fiberglass Rtd Extension Wire Compensation Cable
  • Fiberglass Rtd Extension Wire Compensation Cable
  • Fiberglass Rtd Extension Wire Compensation Cable
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
Overview

Basic Info.

Model NO.
Type K / J / E / N / T / R / S / B
Application
Thermocouple Connection
Conductor Material
Copper
Sheath Material
Fiberglass
Insulation Material
Fiberglass
Material Shape
Round Wire
Range of Application
Sensor Control
Certification
ISO9001, CE
Insulated
Fiberglass, PVC, FEP, PFA
Standard
ANSI, JIS, IEC
Shielding Materials
Silver or Tinned Copper
Packing
Wooden Case
Usage
Industrial
Transport Package
in Roll
Specification
2*7/0.2
Trademark
no
Origin
China
HS Code
8544491900
Production Capacity
10, 0000

Packaging & Delivery

Package Size
27.00cm * 27.00cm * 27.00cm
Package Gross Weight
7.000kg

Product Description

Fiberglass Rtd Extension Wire Compensation Cable

Fiberglass Rtd Extension Wire Compensation Cable
Product Description

 

1. Introduction:
Thermocouple Extension cable is usually used to connect thermocouple and display-controled meters in order to lower the inaccuracy caused by temperature change on the connections.

2. Construction:  
Conductor: original thermocoupole alloy material, in solid wire or strand wires
Insulation Layer:
Fiberglass              (ambient temperature range 0-300ºC
 PVC                       (ambient temperature range 0-105ºC)
 Telflon                  (ambient temperature range 0-350ºC)
 Silicone rubber   (ambient temperature range 0-180ºC)
Jacket layer materials: fiberglass, PVC, teflon, silicone rubber
Galvanized layer: stainless steel, tinned brass

3.Standard: conforms to IEC584 standard.

4. Color Code:Table 1
Fiberglass Rtd Extension Wire Compensation Cable
Product Parameters

 


RTD Extension wire Type RTD-FG/FG/SSB -3×26AWG
Description:

1, SUBJECT
This specification covers the requirements for FB insulated, FB sheathed and stainless steel
braid RTD extension cable, 3×7/0.15mm, strand wire, twisted construction.

2, TECHNICAL FEATURES

A. Conductors:
Stranded RTD extension wire
                                                       
       Conductor        Conductors Size(AWG)        NO.of Strands & Gauge
       Copper or Nickel        26        7/0.15mm

                       
B. Insulation:
Braided fiberglass (400ºC)
                                           
       Nominal Insulation Thickness        0.45mm±0.2mm
       Color code        Red/ Red/White (2 cores red and 1 core white)

C. Assembly:
Three conductors (cores) twisted construction.

D. Overall Jacket
Braided fiberglass (400ºC)                                            
       Nominal Sheath Thickness        0.25mm±0.2                    
       Color code        white

E. Metal Overbraid
Stainless steel round wire braid, 85% minimum coverage

3, DIMENSIONS AND TOLERANCES
                       
       Dimensions/tolerances(mm)        Ø3.0±0.25                        

Various kinds of extension wire can be customized according to your demands.
               
6. How to select:Order Code: e.g.
J 2*7/0.3 FG FG SS DIN
  1                           2                                  3                                     4                          5                       6

1  Thermocouple Types: K, J, E, T, N, S          RTD: Cu, Ni

2  Conductot dimension:
2*7/0.3 means 2 cores,  each core includes 7 strands wire,
each wire diameter is 0.3mm, more example: 2×7/0.2, 2×4/0.65, 2×1/0.3 etc.
Other way to symbol the conductor dimensions:
Conductor square meter: 0.25mm²
AWG standard (see*Table 2)

3 Insulated layer materials:
FG: fiberglass   PVC: PVC      TF: teflon        SR: silicone rubber

4 Jacket layer material
FG: fiberglass   PVC: PVC      TF: teflon        SR: silicone rubber

5 Galvanized Layer material:   SS: stainless steel  TB: tinned brass

6Color Code:
ANSI: American standard   DIN: Germany standard    BS:Britain standard
NFC: France Standard          JIS: Japan Standard           IEC: IEC standard
Detailed Photos

 

 
Fiberglass Rtd Extension Wire Compensation Cable
Fiberglass Rtd Extension Wire Compensation Cable
Fiberglass Rtd Extension Wire Compensation Cable

 

Fiberglass Rtd Extension Wire Compensation Cable
Fiberglass Rtd Extension Wire Compensation Cable
Fiberglass Rtd Extension Wire Compensation Cable
 
Fiberglass Rtd Extension Wire Compensation Cable
Fiberglass Rtd Extension Wire Compensation Cable











 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier