J-type FEP insulated solid core 24AWG-2x1/0.5 thermocouple wire
Product Description
1. Thermocouple Wire Introduction:
Thermocouple wire, also called thermocouple cable and thermocouple compensate wires.
The compensating conductor is a pair of conductors with an insulating layer at a nominal temperature range (0 to 100 ° C), having the same nominal value as the matching thermocouple thermoelectromotive force, connecting them to thermocouples and measuring devices to compensate for their relationship with thermoelectric.
The error caused by the temperature change at the junction.
2. Construction:
Conductor: Original thermocoupole alloy material, in solid wire or strand wires
Insulation Layer:
Fiberglass (ambient temperature range 0-300ºC
PVC (ambient temperature range 0-105ºC)
Telflon (ambient temperature range 0-350ºC)
Silicone rubber (ambient temperature range 0-180ºC)
Jacket layer materials: Fiberglass, PVC, FEP, silicone rubber
Galvanized layer: Stainless steel, tinned brass
Wire Code |
Specification |
Description |
Temp. Range |
KX-FG/FG-0.8 X 2 |
0.8 X 2 |
Glass Fiber/Glass Fiber |
0~400 |
KX-FG/FG-7/0.3 X 2 |
7/0.3 X 2 |
Glass Fiber/Glass Fiber |
0~400 |
JX-FG/FG/SSB-0.5 X 2 |
0.5 X 2 |
Glass Fiber/Glass Fiber |
0~400 |
Stainless Steel Braid |
JX-FG/FG/SSB-7/0.2 X 2 |
7/0.2 X 2 |
Glass Fiber/Glass Fiber |
0~400 |
Stainless Steel Braid |
KX-FG/FG/H-0.6 X 2 |
0.6 X 2 |
High Temp. Glass Fiber |
0~800 |
KX-VS/VS-0.8 X 2 |
0.8 X 2 |
Vitreous Silica/Vitreous Silica |
0~980 |
KX-CF/CF-1 X 2 |
0.8 X 2 |
Ceramics Fiber/Ceramics Fiber |
0~1100 |
KX-PVC/PVC-0.6 X 2 |
0.6 X 2 |
PVC /PVC |
0~105 |
KX-PVC/PVC-4/0.3 X 2 |
4/0.3 X 2 |
PVC /PVC |
0~105 |
JX-PVC/PVC/SSB-7/0.2 X 2 |
7/0.2 X 2 |
PVC /PVC |
0~105 |
Stainless Steel Braid |
KX-TEF/TEF-0.3 X 2 |
0.3 X 2 |
FEP |
0~200 |
JX-TEF/TEF-4/0.6 X 2 |
4/0.6X 2 |
FEP |
0~200 |
TX-PFA/PFA-7/0.2 X 2 |
7/0.2 X 2 |
PFA /PFA |
0~260 |
KX-PFA/PFA-0.15 X 2 |
0.15 X 2 |
PFA /PFA |
0~260 |
KX-SIL/SIL-7/0.6 X 2 |
7/0.6 X 2 |
Sillicon/Sillicon |
0~250 |
JX-FG/SIL-7/0.2 X 2 |
7/0.2 X 2 |
Glass Fiber/Sillicon |
0~250 |
JX-KPT/KPT-7/0.2 X 2 |
7/0.2 X 2 |
KAPTON/KAPTON |
0~400 |
TX-KPT/KPT-19/0.3 X 2 |
19/0.3 X 2 |
KAPTON/KAPTON |
0~400 |
RTD-FEP/CU/SIL-7/0.12 X 4 |
7/0.12 X 4 |
FEP |
0~200 |
Cu Braid |
Sillicon Sheath |
RTD-TEF/TEF- 0.12 X 6 |
0.12 X 6 |
FEP |
0~200 |
RTD-PFA/PFA- 7/0.2 X 3 |
7/0.2 X 3 |
PFA /PFA |
0~260 |
RTD-KPT/KPT- 7/0.2 X 3 |
7/0.2 X 3 |
KAPTON/KAPTON |
0~400 |
3. Standard: Conforms to IEC584 standard.
4. Color Code: Table 1
Product Parameters
5. Fiberglass Thermocouple Wire
Conductors
Wire Sizes(mm) |
Section(mm²) |
AWG |
2X1/0.2 |
Approx. 0.03 |
32 |
2X1/0.5 |
Approx. 0.20 |
24 |
2X1/0.65 |
Approx. 0.33 |
22 |
2X1/0.8 |
Approx. 0.50 |
20 |
2X7/0.2 |
Approx. 0.22 |
24 |
2X7/0.3 |
Approx. 0.50 |
20 |
2X6/0.32 |
Approx. 0.48 |
20 |
Color code:
ANSI: American standard
DIN: Germany standard
BS: Britain standard
NFC: France Standard
JIS: Japan Standard
IEC: IEC standard
Types Available: K, J, E, T, N, S
1>. Constructure: Fiberglass +fiberglass
Conductors are fiberglass insulated
Overall fiberglass jacket
Max. Environment temperature: 400ºC
2>. Constructure: Fiberglass +stainless steel braided (FG+SSB)
Conductors are fiberglass insulated
Overall stainless steel braided jacket for shielding.
Max. Environment temperature: 400ºC
3>. Constructure: Fiberglass +fiberglass +stainless steel braided (FG+FG+SSB)
Conductors are fiberglass insulated
Overall fiberglass jacket
Stainless steel braided jacket shielding.
Max. Environment temperature: 400ºC
4>. Constructure: Fiberglass +FEP (FG+TF)
Conductors are fiberglass insulated
Overall FEP jacket,
Max. Environment temperature: 400ºC
6. FEP Thermocouple Wire
Conductors
Wire Sizes(mm) |
Section(mm²) |
AWG |
2X1/0.2 |
Approx. 0.03 |
32 |
2X1/0.5 |
Approx. 0.20 |
24 |
2X1/0.65 |
Approx. 0.33 |
22 |
2X1/0.8 |
Approx. 0.50 |
20 |
2X7/0.2 |
Approx. 0.22 |
24 |
2X7/0.3 |
Approx. 0.50 |
20 |
2X6/0.32 |
Approx. 0.48 |
20 |
Color code:
ANSI: American standard
DIN: Germany standard
BS: Britain standard
NFC: France Standard
JIS: Japan Standard
IEC: IEC standard
Type available: K, J, E, T, N, S
1 >*Constructure: FEP + FEP(TF + TF)
Conductors are FEP insulated
Overall FEPjacket
Max. Environment temperature: 200ºC
2 > Constructure:FEP
+FEP
(TF + TF Twisted )
Conductors are FEP insulated
Two wires twisted
Overall FEP jacket,
Max. Environment temperature: 200ºC
3> Constructure: FEP
+ Stainless Steel Braided (TF + SSB )
Conductors are FEP insulated
Overall stainless steel braided jacket.
Max. Environment temperature: 200ºC
4> Constructure: FEP
+ Stainless Steel Braided+ FEP
(TF + SSB +TF )
Conductors are FEP insulated
Stainless steel braided for shieding in the middle
Overall FEP jacket.
Max. Environment temperature: 200ºC
7. PVC Thermocouple Wire
Conductors
Wire Sizes(mm) |
Section(mm²) |
AWG |
2X1/0.2 |
Approx. 0.03 |
32 |
2X1/0.5 |
Approx. 0.20 |
24 |
2X1/0.65 |
Approx. 0.33 |
22 |
2X1/0.8 |
Approx. 0.50 |
20 |
2X7/0.2 |
Approx. 0.22 |
24 |
2X7/0.3 |
Approx. 0.50 |
20 |
2X6/0.32 |
Approx. 0.48 |
20 |
Color code:
ANSI: American standard
DIN: Germany standard
BS: Britain standard
NFC: France Standard
JIS: Japan Standard
IEC: IEC standard
Type Available: K, J, E, T, N, S
1>. Constructure: PVC + PVC ( PVC + PVC )
Conductors are PVC insulated
Overall PVC jacket
Max. Environment temperature: 105ºC
2>. Constructure: PVC + Stainless Steel + PVC ( PVC + SSB+ PVC )
Conductors are PVC insulated
Stainless steel braided for shieding in the middle
Overall PVC jacket
Max. Environment temperature: 105ºC
8. Thermocouple cable Silicone Rubber type
Conductors
Wire Sizes(mm) |
Section(mm²) |
AWG |
2X1/0.2 |
Approx. 0.03 |
32 |
2X1/0.5 |
Approx. 0.20 |
24 |
2X1/0.65 |
Approx. 0.33 |
22 |
2X1/0.8 |
Approx. 0.50 |
20 |
2X7/0.2 |
Approx. 0.22 |
24 |
2X7/0.3 |
Approx. 0.50 |
20 |
2X6/0.32 |
Approx. 0.48 |
20 |
Color code:
ANSI: American standard
DIN: Germany standard
BS: Britain standard
NFC: France Standard
JIS: Japan Standard
IEC: IEC standard
Type Available: K, J, E, T, N, S
1>. Constructure: Silicone Rubber + Silicone Rubber ( SR + SR)
Conductors are silicone rubber insulated
Overall silicone rubber jacket
Max. Environment temperature: 200ºC
2>. Constructure: Quartz Fiber + Quartz Fiber ( QF + QF)
Conductors are quartz fiber insulated
Overall quartz fiber jacket
Max. Environment temperature: 1000ºC
3>. Constructure: Kapton + Kapton ( KP + KP)
Conductors are kapton insulated
Overall kapton jacket
Max. Environment temperature: 400ºC
9. RTD cable
Conductors
Wire Sizes(mm) |
3X1/0.2 |
3X1/0.5 |
3X1/0.65 |
3X1/0.8 |
3X7/0.2 |
3X7/0.3 |
3X6/0.32 |
Type available: No
Color code: No
1>. Constructure: Silicone Rubber + Silicone Rubber ( SR + SR)
RTD extension cable
Conductors could be copper or nickel. Are silicone rubber insulated
Overall silicone rubber jacket
Max. Environment temperature: 200ºC
2>. Constructure: FEP
+ Stainless Steel +FEP
( TF + SSB + TF )
RTD cable
Conductors could be copper or nickel
Conductors are FEP insulated
Stainless steel braided for shieding in the middle
Overall silicone rubber jacket
Max. Environment temperature: 200ºC
Detailed Photos