FEP Thermocouple Wire for Temperature Sensor

Product Details
Customization: Available
Installation Type: Duct Type
Sensing Type: Thermocouple
Still deciding? Get samples of US$ 0/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2018

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
500000 RMB
Plant Area
<100 square meters
  • FEP Thermocouple Wire for Temperature Sensor
  • FEP Thermocouple Wire for Temperature Sensor
  • FEP Thermocouple Wire for Temperature Sensor
  • FEP Thermocouple Wire for Temperature Sensor
  • FEP Thermocouple Wire for Temperature Sensor
  • FEP Thermocouple Wire for Temperature Sensor
Find Similar Products
  • Overview
  • Product Description
Overview

Basic Info.

Model NO.
Type K / J / E / N / T / R / S / B
Contact
Contact
Output Signal Type
Digital Type
Certification
CE
Customized
Customized
Conductor Type
Solid, Solid or Stranded
Insulated
Fiberglass, PVC, FEP, PFA
Standard
ANSI, JIS, IEC
Shielding Materials
Silver or Tinned Copper
Packing
Wooden Case
Usage
Industrial
Transport Package
in Roll
Specification
2*7/0.2
Trademark
no
Origin
China
HS Code
8544491900
Production Capacity
10, 0000

Packaging & Delivery

Package Size
23.00cm * 23.00cm * 23.00cm
Package Gross Weight
6.000kg

Product Description

FEP Thermocouple Wire for Temperature Sensor Type K, J, E, T, N, S
FEP Thermocouple Wire for Temperature Sensor
 
Product Description

 

1. Introduction:
Thermocouple wire is usually used to connect thermocouple and display-controled meters in order to lower the inaccuracy caused by temperature change on the connections.

2. Construction:  
Conductor: original thermocoupole alloy material, in solid wire or strand wires
Insulation Layer:
Fiberglass              (ambient temperature range 0-300ºC
 PVC                       (ambient temperature range 0-105ºC)
 TF                         (ambient temperature range 0-350ºC)
 Silicone rubber   (ambient temperature range 0-180ºC)
Jacket layer materials: fiberglass, PVC, TF, silicone rubber
Galvanized layer: stainless steel, tinned brass

FEP Thermocouple Wire for Temperature Sensor

3.Standard: conforms to IEC584 standard.

4. Color Code:Table 1
FEP Thermocouple Wire for Temperature Sensor


 5. Comparison between AWG standard and metric standard. Table 2
FEP Thermocouple Wire for Temperature Sensor

6. Parameters
Type of Compensating 
Conductor
Equipped Thermocouple Thermocouple 
Index
Compensating 
Conductor 
Allong-wire
Insulation Layer 
Coloration
Positive Negative Positive Negative
SC PtRh10-Platinum thermocouple10 S SPC   Cu SNC
Cu   Ni
Red Green
RC PtRh13-Platinum thermocouple13 R RPC   Cu RNC Cu Ni Red Green
KCA/KCB/KX Ni Cr- Nisi-loy Thermocouple K KPCA Fe/
KPCB Cu/
KPX Ni Cr
KNCA Cu Ni/
KNCB Cu Ni/
KNX Ni Si
Red Blue/
Blue/
Black
NC/NX Ni Cr- Nisi-loy Thermocouple N NPC Fe
NPX
Ni Cr Si
NNC Cu Ni
NNX Ni Si
Red Grey
Grey
EX Ni Cr- Copper-nickel Thermocouple E EPX Ni Cr ENX Cu Ni Red Brown
JX Fe- Copper-nickel Thermocouple J JPX Fe JNX Cu Ni Red Purple
TX Cu- Copper-nickel
Thermocouple
T TPX Cu TNX Cu Ni Red White
 
Section
(sq.mm)
Single-strand core Multi-strand core Insulation 
Thickness
(mm)
Sheath Thickness
(mm)
Line cores Diameter
(mm)
Cores Diameter
(mm)
0.2 1 0.5 7 0.2 0.4 0.3
0.5 1 0.8 7 0.3 0.4 0.3
1 1 0.13 7 0.43 0.4 0.3
1.5 1 1.37 7 0.52 0.4 0.3
2.5 1 1.76 19 0.41 0.4 0.3
 

7. How to select:Order Code: e.g.
J 2*7/0.3 FG FG SS DIN
  1                           2                                  3                                     4                          5                       6

1  Thermocouple Types: K, J, E, T, N, S          RTD: Cu, Ni

2  Conductot dimension:
2*7/0.3 means 2 cores,  each core includes 7 strands wire,
each wire diameter is 0.3mm, more example: 2×7/0.2, 2×4/0.65, 2×1/0.3 etc.
Other way to symbol the conductor dimensions:
Conductor square meter: 0.25mm²
AWG standard (see*Table 2)

3 Insulated layer materials:
FG: fiberglass   PVC: PVC      TF        SR: silicone rubber

4 Jacket layer material
FG: fiberglass   PVC: PVC      TF        SR: silicone rubber

5 Galvanized Layer material:   SS: stainless steel  TB: tinned brass

6Color Code:
ANSI: American standard   DIN: Germany standard    BS:Britain standard
NFC: France Standard          JIS: Japan Standard           IEC: IEC standard

8. Photos for reference.
FEP Thermocouple Wire for Temperature Sensor
FEP Thermocouple Wire for Temperature SensorFEP Thermocouple Wire for Temperature SensorFEP Thermocouple Wire for Temperature Sensor
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier